logo
Casa ProdottiSensore del gas

MPn-4C CH4 Methane Flammable Gas Sensor For Manufacturing Process

Certificazione
La CINA ShenzhenYijiajie Electronic Co., Ltd. Certificazioni
La CINA ShenzhenYijiajie Electronic Co., Ltd. Certificazioni
Sono ora online in chat

MPn-4C CH4 Methane Flammable Gas Sensor For Manufacturing Process

MPn-4C CH4 Methane Flammable Gas Sensor For Manufacturing Process
MPn-4C CH4 Methane Flammable Gas Sensor For Manufacturing Process MPn-4C CH4 Methane Flammable Gas Sensor For Manufacturing Process

Grande immagine :  MPn-4C CH4 Methane Flammable Gas Sensor For Manufacturing Process

Dettagli:
Place of Origin: CN
Marca: IRS4
Model Number: MPn-4C
Termini di pagamento e spedizione:
Minimum Order Quantity: 1PCS
Prezzo: Negoziabile
Packaging Details: Standard packaging
Delivery Time: 5-8 work days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 5000PCS

MPn-4C CH4 Methane Flammable Gas Sensor For Manufacturing Process

descrizione
Loop voltage: ≤ 24 V DC Heater voltage: ± 0.1 V AC or DC
Heater Consumption: PH ≤ 350 mW Sensitive Resistance: RS 1 kΩ - 20 kΩ (in 5000 ppm CH4)
O2 Content: 21 % Lifespan: 10 years
Evidenziare:

CH4 methane gas sensor

,

flammable gas sensor for manufacturing

,

MPn-4C methane detector

 

                             MPn-4C CH4 Methane Flammable Gas Sensor For Manufacturing Process 

 

      Target Gas: CH4, methane, natural gas, marsh gas

  • Detection Range: 300 - 10000 ppm (methane, natural gas)
  • Detection Principle: Semiconductor
  • Characteristics: High sensitivity to CH4 gas, excellent anti - interference ability, excellent stability
  • Manufacturing Process: Adopts a multi - layer thick film manufacturing process, which integrates a heating electrode, a measuring electrode and a metal oxide semiconductor gas - sensitive layer on an Al2O3 ceramic substrate, and encapsulates it in a metal housing.
  • Working Principle: When the detected gas is present in the ambient air, the conductivity of the sensor will change, and the higher the concentration of the gas, the higher the conductivity of the sensor. This change in conductivity can be converted into an output signal corresponding to the gas concentration using a simple circuit.
  • Application: Widely used in combustible gas leak monitoring devices, fire/safety detection systems for home, factory and commercial use; flammable gas leak alarm, gas leak detector, etc.

 

Model MPn - 4C
Target Gas CH4, Natural Gas, Marsh Gas
Detection Range 300 - 10000 ppm (methane, natural gas)
Detection Principle Semiconductor
Standard Circuit Conditions Loop voltage VC ≤ 24 V DC
Heater voltage VH 5 V ± 0.1 V AC or DC
Load resistance RL adjustable
Heater Consumption PH ≤ 350 mW
Sensitive Resistance RS 1 kΩ - 20 kΩ (in 5000 ppm CH4)
Sensitivity S = RS (in air) / RS (5000 ppm CH4) ≥ 8
Concentration Slope α ≤ 0.6 (R5000 ppm / R1000 ppm CH4)
Standard Test Conditions Temperature 20 ℃ ± 2 ℃; Humidity 55 % ± 5 % RH
Standard Test Circuit VC: 5 V ± 0.1 V; VH: 5 V ± 0.1 V
Preheat Time Not less than 48 hours
O2 Content 21 % (not less than 18 %)
Lifespan 10 years
Sensor Type Flat - surfaced
Standard Encapsulation Metal cap

 

MPn-4C CH4 Methane Flammable Gas Sensor For Manufacturing Process 0

 

Dettagli di contatto
ShenzhenYijiajie Electronic Co., Ltd.

Persona di contatto: Miss. Xu

Telefono: 86+13352990255

Invia la tua richiesta direttamente a noi (0 / 3000)