logo
Casa ProdottiSensore ad ossigeno e gas

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

Certificazione
La CINA ShenzhenYijiajie Electronic Co., Ltd. Certificazioni
La CINA ShenzhenYijiajie Electronic Co., Ltd. Certificazioni
Sono ora online in chat

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices
YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

Grande immagine :  YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

Dettagli:
Luogo di origine: Gran Bretagna
Marca: YJJ
Numero di modello: O2-C2
Termini di pagamento e spedizione:
Quantità di ordine minimo: 1
Prezzo: Negoziabile
Imballaggi particolari: Palletizzato
Tempi di consegna: 5-8 giorni
Termini di pagamento: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Capacità di alimentazione: 2200

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

descrizione
Intervallo di misurazione: 0 - 30% di concentrazione di ossigeno Uscita corrente: 80 - 120 μA
Resistenza al carico: 47 - 100 ohm Tempo di risposta: T90 (dal 20,9% allo 0%) <45 secondi
Temperatura operativa: -30 a 55℃ Gamma di umidità: 5 - 95% di RH
Intervallo di pressione: 80 - 120 KPa Misurare: 20,3 × 23 mm
Evidenziare:

electrochemical oxygen sensor 0-30% range

,

oxygen alarm device sensor

,

YJJ O2-C2 oxygen sensor

Product Description:

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

 

Features:

Main parameters of the O2-C2 oxygen sensor are as follows:

Measurement range

0 - 30% oxygen concentration

Output signal

Current output: 80 - 120 μA (at 22℃, 20.9% oxygen)

Load resistance: 47 - 100 ohms

Response time

T90 (from 20.9% to 0%) < 45 seconds

Environmental adaptability

Operating temperature: -30 to 55℃

Humidity range: 5 - 95% RH

Pressure range: 80 - 120 kPa

Other features

Size: Φ20.3 × 23mm

Weight: < 18g

Storage period: 6 months (sealed preservation)

Linear error: ±0.6% of the full range

Application fields: Oxygen alarm device, atmosphere analyzer

 

Specifications:

Range 0 - 30 ppm
Sensitivity 1.9 ± 0.8 μA/ppm (at 20℃)
Baseline range -0.2 to 2.5 μA (@20℃)
Response time ≤ 45seconds (T90)

 