SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting

Grande immagine :  SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting

Dettagli:
Luogo di origine: Regno Unito
Marca: SGX
Numero di modello: SGX-4OX
Termini di pagamento e spedizione:
Quantità di ordine minimo: 1
Prezzo: Negoziabile
Imballaggi particolari: Pacchetto standard
Tempi di consegna: 3-5 giorni di lavorazione
Termini di pagamento: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Capacità di alimentazione: 3000pc/mesi

SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting

descrizione
Allineare: 0-25%02 Corrente zero (offset): <0,6% v/v O2
Segnale in uscita in aria: Da 70 a 130 μA Tempo di risposta (T90): <15 anni
Evidenziare:

oxygen gas sensor through hole

,

portable oxygen gas detector

,

SGX-4OX gas sensor

SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting

 

POISONING
SGX sensors are designed to operate in a wide range of harsh environments and conditions. However it is important that exposure to high concentrations of solvent vapours is avoided during storage, fitting into instruments and operation.When using sensors on
printed circuit boards(PCBs),degreasing agents should be used prior to the sensor being fitted.

 

ACID GASES
Acid gases such as CO,and SO, will be absorbed by the electrolyte and tends to increase the flux of oxygen to the electrode. This gives an enhanced oxygen signa of approximately 0.3% of signal per 1% CO.. The SGX 40X sensors are not suitable for continuous operation
in concentrations of CO, above 25%.

 

Specification:

Maximum Overload 30%  02
Long-term Output Drift  <5% per annum
Recommended Load Resistor  100 ohms