                        Dettagli:
                                                     
 
 | 
| Intervallo di misurazione: | 0 - 10.000 ppm | Tempo di risposta: | t90 < 50s da zero a 2.000 ppm di CO | 
|---|---|---|---|
| Risoluzione: | < 5 valore efficace | Zero corrente: | <± 20 ppm | 
| Intervallo di temperatura: | da -30 a 50°C | Intervallo di pressione: | da 80 a 120 kPa | 
| Evidenziare: | CO-AE carbon monoxide gas sensor,portable CO detector sensor,residential commercial carbon monoxide sensor | ||
CO-AE Carbon Monoxide Gas Sensor For Portable Carbon Monoxide (CO) Detectors Residential Commercial
Features:
Applications (Product Uses):
| Measurement Range | 0 - 10,000 ppm | 
| Over Gas Range | 100,000 ppm | 
| Sensitivity | 10 - 25 nA/ppm in 2,000 ppm CO | 
| Response Time (t90) | < 50s from zero to 2,000 ppm CO | 
| Resolution | < 5 rms noise (ppm equivalent) | 
| Zero Current | < ± 20 ppm equivalent in zero air | 
| Temperature Range | -30 to 50 °C | 
| Pressure Range | 80 to 120 kPa | 
| Humidity Range | 15 to 90% RH continuous | 
| Storage Period | 6 months @ 3 to 20 °C (stored in sealed pot) | 
| Load Resistor | 10 to 47 Ω | 
| Weight | < 6 g | 
| H2S Sensitivity | < 0.1% measured gas @ 20 ppm H2S | 
| NO2 Sensitivity | < 0.1% measured gas @ 10 ppm NO2 | 
| Cl2 Sensitivity | < 0.2% measured gas @ 10 ppm Cl2 | 
| NO Sensitivity | < 0.1% measured gas @ 50 ppm NO | 
| SO2 Sensitivity | < 0.1% measured gas @ 20 ppm SO2 | 
| H2 Sensitivity | < 75% measured gas @ 400 ppm H2 at 20 °C | 
| C2H4 Sensitivity | < 60% measured gas @ 400 ppm C2H4 | 
| NH3 Sensitivity | < 0.1% measured gas @ 20 ppm NH3 | 
| Sensitivity @ -20 °C | 65 - 93% (output @ -20 °C / output @ 20 °C) @ 400 ppm CO | 
| Sensitivity @ 50 °C | 98 - 115% (output @ 50 °C / output @ 20 °C) @ 400 ppm CO | 
| Zero @ -20 °C | < ± 2 ppm equivalent change from 20 °C | 
| Zero @ 50 °C | < ± 5 ppm equivalent change from 20 °C | 