logo
Casa ProdottiSensore del gas

HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection

Certificazione
La CINA ShenzhenYijiajie Electronic Co., Ltd. Certificazioni
La CINA ShenzhenYijiajie Electronic Co., Ltd. Certificazioni
Sono ora online in chat

HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection

HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection
HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection

Grande immagine :  HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection

Dettagli:
Luogo di origine: Regno Unito
Marca: Alphasense
Numero di modello: hcn-a1
Termini di pagamento e spedizione:
Quantità di ordine minimo: 1
Prezzo: Negoziabile
Imballaggi particolari: Pacchetto standard
Tempi di consegna: 3-5 giorni di lavorazione
Termini di pagamento: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Capacità di alimentazione: 10000 pezzi/mese

HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection

descrizione
Intervallo di misurazione: 100 ppm Sensibilità: 30ppm
Corrente di punto zero: <±2 ppm Risoluzione: <0,05 ppm
Evidenziare:

hydrogen cyanide gas sensor

,

chemical leak detection sensor

,

HCN-A1 gas sensor

HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection

 

The HCN-A1 electrochemical hydrogen cyanide gas sensor is commonly used in chemical leak detection, environmental monitoring, and other applications.

 

Physical and usage cycle parameters

Dimensions Diameter 20.2mm, Overall height 16.5mm (including label), Dimensional tolerance ±0.15mm
Weight <6 grams
Operating life Output signal drops to 80% of initial value in over 12 months, official 12-month warranty
Storage period 6 months in a sealed environment at 3-20℃

 

Environment adaptation parameters

Operating temperature -30~50°C; sensitivity at -20°C is 75-95% of that at 20°C, and sensitivity at 50°C is 105-120% of that at 20°C.
Operating humidity 15-90% RH (continuous operation)
Operating pressure 80-120 kPa
Temperature effect on zero point zero-point change relative to 20°C at -20°C < 0-1 ppm; zero-point change relative to 20°C at 50°C < ±1 ppm.

 

Electrical and interference related parameters

Recommended load resistor 10 - 33Ω
Bias requirement No additional bias voltage required

 